Mass Flow Controllers (MFC)

Precision Gas Flow Measurement and Control

Measflow mass flow controllers provide precise gas flow measurement and closed-loop flow control for industrial processes, laboratory equipment, gas mixing systems and semiconductor-related applications.

From low-flow gas dosing to higher-capacity process control, we offer thermal, differential pressure and Coriolis mass flow controller solutions based on your gas type, flow range and operating conditions.

Mass Flow Controller Product Range

Choose the appropriate mass flow controller technology according to your gas properties, required flow range, accuracy and process conditions.

1. Digital Thermal Mass Flow Controller

Thermal mass flow controllers are designed for gas flow measurement and control in a wide range of industrial and laboratory applications. Digital models can support electronic flow setting, measurement feedback and configurable communication interfaces.

  • Suitable for many common process gases

  • Compact design for equipment integration

  • Configurable analog and digital interfaces

  • Multiple flow ranges available

2. Differential Pressure Mass Flow Controller

Differential pressure mass flow controllers use differential pressure measurement and a control valve to regulate gas flow. They are suitable for selected applications requiring stable flow control under defined pressure conditions.

  • Differential pressure-based measurement

  • Closed-loop flow regulation

  • Configurable pressure and flow ranges

  • Options for equipment and process integration

3. Coriolis Mass Flow Controller

Coriolis-based solutions are designed for applications requiring direct mass flow measurement. Depending on the model, they can support gas or liquid measurement and control for demanding process requirements.

  • Direct mass flow measurement

  • Suitable for selected gas and liquid applications

  • High-precision process dosing options

  • Model-specific flow and pressure configurations

How Does an MFC Work?

A mass flow controller combines a flow sensor, electronic control circuit and proportional control valve to regulate flow automatically.

Mass flow controller working principle with flow sensor and control valve
Mass flow controller working principle with flow sensor and control valve

The controller measures the actual gas flow and compares it with the user-defined setpoint. The control circuit then adjusts the valve opening to minimize the difference between the measured flow and the target flow.

The control process continuously repeats to maintain the desired flow under suitable operating conditions.

  1. Set the target flow: Enter the required flow rate through a supported analog signal, digital interface or local control system.

  2. Measure the actual flow: The sensor detects the gas flow passing through the instrument.

  3. Compare the flow values: The control circuit compares the measured flow with the setpoint.

  4. Adjust the control valve: The valve opening changes automatically to bring the flow closer to the target value.

Unlike a mass flow meter (MFM), which measures flow without actively regulating it, an MFC combines measurement with automatic flow control.

Why Choose Measflow Mass Flow Controllers?

Precise Flow Control

Select a suitable model according to your accuracy, repeatability and process stability requirements.

Flexible Flow Ranges

Solutions for low-flow dosing and higher-capacity gas control, subject to model specifications.

Multiple Signal Options

Available configurations may include 4–20 mA, voltage signals and digital communication.

Application-Based Configuration

Flow range, gas calibration, pressure rating and connections can be evaluated against your requirements.

Mass Flow Controller Applications

  • Semiconductor and Thin-Film Processing

Gas delivery, deposition, etching and process gas control, subject to required cleanliness and compatibility specifications.

  • Gas Mixing and Blending

Control individual gas streams for blending systems, calibration mixtures and process gas preparation.

  • Laboratory and Analytical Instruments

Stable gas flow delivery for analytical equipment, test benches and laboratory experiments.

  • Fuel Cell and Energy Research

Gas supply and flow regulation for fuel cell testing, hydrogen research and other energy-related processes.

  • Industrial Process Control

Gas dosing, combustion-related systems, process equipment and automated gas delivery applications.

Mass Flow Controller Selection Guide

Selecting the right MFC requires more than specifying the pipe size or nominal flow rate. Gas properties, operating pressure, required accuracy and available pressure differential all affect model suitability.

Selection parameter

Information to provide

Gas type

N₂, Ar, O₂, H₂, CO₂, CH₄, NH₃ or gas mixtures

Flow range

Minimum, normal and maximum flow

Flow unit

SCCM, SLM, NL/min, L/min, g/h or other

Operating pressure

Inlet pressure and outlet pressure

Pressure differential

Available pressure drop across the MFC

Temperature

Minimum and maximum operating temperature

Accuracy

Required accuracy and repeatability

Control signal

Analog setpoint or digital control

Output signal

4–20 mA, voltage, digital output or other

Communication

Modbus RTU, RS485 or other supported protocol

Connections

Port size, thread standard and sealing requirements

Power supply

24 VDC or other specified supply

Special requirements

Corrosive gas compatibility, leakage, cleanliness, Ex or certification requirements

Important: The selected MFC must be compatible with the gas and have sufficient pressure differential to achieve the required flow. Gas-specific calibration, wetted materials and available communication protocols should be confirmed before ordering.

Thermal vs. Differential Pressure vs. Coriolis MFC

Feature

Thermal MFC

Differential Pressure MFC

Coriolis MFC

Measurement principle

Thermal sensing

Differential pressure-based

Coriolis effect

Typical use

Gas flow control

Applications with defined pressure conditions

Direct mass flow measurement

Gas compatibility

Depends on gas calibration

Depends on design and calibration

Depends on model and fluid

Pressure requirements

Model-dependent

Pressure differential is especially important

Model-dependent

Liquid measurement

Generally not the intended use of standard thermal gas models

Design-dependent

Available on suitable models

Selection priority

Gas type and flow range

Pressure conditions and flow range

Accuracy, fluid properties and operating conditions

The best technology depends on your actual process. These categories are not interchangeable in every application; confirm the relevant model specifications before selection.

Find the Right Mass Flow Controller for Your Application

Not sure which MFC technology or flow range is suitable? Send us your gas type, required flow range and operating pressure. Our team can review your requirements and recommend an appropriate configuration.